Instagram Facebook E-mail WhatsApp
PLC Based Automation Solutions and Communication System
+91 9152891323, 9819391323 / response@nimbustechnologies.ae

M-7018R-G

M-7018R-G

8-ch Thermocouple Input Module with High Voltage Protection

Features
  • 8 Differential Analog Inputs
  • Current, Voltage, and Thermocouple Inputs
  • High Over-voltage Input Protection
  • High Common Voltage Protection
  • Built-in Dual Watchdog

  • Introduction
  • Application
  • Specification
  • Download
  • Get A Quote

Introduction

The M-7018/M-7018R is an 8-channel analog input module that supports current, voltage, and thermocouple input. The M-7018R is an upgraded version of the M-7018 that includes an extremely high-quality protection mechanism where the overvoltage protection can be as high as 240 Vrms. The M-7018R is more suitable for critically harsh environments, and the newly-added open thermocouple detection feature makes The M-7018R more attractive than ever.

The M-7018/M-7018R also features 4 kV ESD protection and 3000 VDC intra-module isolation. The M-7018/M-7018R supports Modbus RTU and DCON protocols, which can be configured via software, and all hardware specifications are the same as the I-7018/I-7018R.

Model Analog Input DIO
DCON Modbus/RTU Channels Resolution Sampling Range Sensor Type Open Wire Configurable Overvoltage
I-7011D M-7011D-G 1 diff. 16-bit 10 Hz 15 mV – 2.5 V, 20 mA J, K, T, E, R, S, B, N, C Yes - 5 VDC DIx1 / DOx2
I-7011PD - 1 diff. 16-bit 10 Hz 15 mV – 2.5 V J, K, T, E, R, S, B, N, C, L, M Yes - 5 VDC DIx1 / DOx2
- M-7018-16-G 16 diff. 16-bit 10 Hz Voltage & Current ranges J, K, T, E, R, S, B, N, C Yes - 30 VDC -
I-7018-G M-7018-G 8 diff. 16-bit 10 Hz Voltage & Current ranges J, K, T, E, R, S, B, N, C - - 120 VDC -
I-7018P-G - 8 diff. 16-bit 10 Hz Voltage & Current ranges J, K, T, E, R, S, B, N, C, L, M - - 80 VDC -
I-7018R-G M-7018R-G 8 diff. 16-bit 10 Hz Voltage ranges J, K, T, E, R, S, B, N, C Yes Yes 240 Vrms -
I-7019R M-7019R-G 8 diff. 16-bit 10 Hz Extended voltage/current J, K, T, E, R, S, B, N, C, L, M Yes Yes 240 Vrms -
I-7018Z-G/S M-7018Z-G/S 10 diff. 16-bit 10 Hz ± ranges + current J, K, T, E, R, S, B, N, C, L, M Yes Yes 240 Vrms -
- M-7019Z-G/S 10 diff. 16-bit 10 Hz Extended ± ranges J, K, T, E, R, S, B, N, C, L, M Yes Yes 240 Vrms -

Notes:

  • External 125 Ω resistors required
  • Supports DI / DO / Alarm modes
  • Jumper selectable ranges

Application

Specification

CPU Module
Watchdog Timer Module, Communication (Programmable)
Isolation
Intra-module Isolation 3000 VDC
EMS Protection
EFT (IEC 61000-4-4) ±4 kV for Power Line
ESD (IEC 61000-4-2) ±4 kV Contact for Each Terminal
Surge (IEC 61000-4-5) ±0.5 kV for Power Line
LED Indicators
Status 1 x Power and Communication
Analog Input
Channels 8 Differential
Type Voltage
Current
Thermocouple
Sensor Type Thermocouple: J, K, T, E, R, S, B, N, C
Range Voltage: ±15 mV, ±50 mV, ±100 mV, ±500 mV, ±1 V, ±2.5 V
Current: ±20 mA, 0 ~ +20 mA, +4 ~ +20 mA (requires an optional external 125 Ω resistor)
Resolution 16-bit
Accuracy ±0.1% of FSR
Sampling Rate 10 Hz (Total)
Input Impedance > 400 kΩ
Common Voltage Protection 200 VDC
Overvoltage Protection 240 Vrms
Overcurrent Protection Yes
Individual Channel Configuration Yes (*Note1)
Open Wire Detection For Thermocouple Only (Software Selectable, *Note2)
COM Ports
Ports 1 x RS-485
Baud Rate 1200 ~ 115200 bps
Data Format (N, 8, 1), (N, 8, 2), (E, 8, 1), or (O, 8, 1)
Protocol Modbus RTU, DCON
Power
Reverse Polarity Protection Yes
Input Range +10 ~ +30 VDC
Consumption 1.0 W
Mechanical
Dimensions (mm) 72 x 123 x 35 (W x L x H)
Installation DIN-Rail Mounting
Environment
Operating Temperature -25 ~ +75 °C
Storage Temperature -40 ~ +85 °C
Humidity 10 ~ 95% RH, Non-condensing

Download

R2010-4L NT-RTU-2022 Utility Tools

ENQUIRY