CL-223-E

CL-223-E

PM1/PM2.5/PM10/CO/CO2/Temperature/Humidity/Dew Point Data Logger Module

Features

  • Able to record PM1/PM2.5/PM10, CO, CO2, Temperature, Humidity and Dew Point
  • Non-dispersive Infrared (NDIR) CO2 Sensor
  • Up to 450,000 records with date and time stamps
  • Web-based Configuration Interface
  • Simple and Powerful Software Utility, iOS App and Android App Included
  • Supports the DCON, Modbus RTU/TCP, and MQTT Protocols
  • Features RS-485/Ethernet/PoE Communication Interfaces
  • Relay Output for Alarm or IAQ Device Control

  • Introduction
  • Application
  • Specification
  • Download
  • Get A Quote

Introduction

The CL-220 series of data logger devices can be used to record PM1/PM2.5/PM10 and the number of particles (0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm), CO, CO2, NH3 , H2S, HCHO, TVOC, temperature, humidity and dew point information, including the date and time stamps, and are able to store up to 450,000 downloadable records.

Real-time data can be accessed from the CL-200 data logger from anywhere and at any time using the free Windows software, the iOS App, or the Android App, as long as they are connected to the same local network as the data logger.

Support is provided for common industrial protocols such as DCON, Modbus RTU, and Modbus TCP, as well as the emerging machine-to-machine (M2M)/)IoT (Internet of Things) connectivity protocol - MQTT. The CL-200 data logger can be connected via widely used communication interfaces including RS-485, Ethernet and PoE, meaning that the device can be easily integrated into existing HMI or SCADA systems, ensuring trouble-free maintenance in distributed control systems.

Supports the MQTT Protocol for IoT Applications
CL-223-E
Multi-platform Remote Access Software

Real-time data from the CL-200 data logger can be accessed from anywhere and at any time using the iAir Utility, the iOS or Android App, or via a regular web browser, as long as they are connected to the same local network as the data logger.

CL-223-E
Simple and Powerful iAir Utility

The iAir Utility is a powerful tool that is designed for configuring the modules, monitoring real-time data, grouping CL-200 modules to view and manage the status of distribution groups, downloading log data, which can be exported to a CSV fi le that can then be imported into any industry-standard software or spreadsheet for analysis.

CL-223-E
Models Accessory Sensor Type
RS-485 Ethernet/PoE Wi-Fi Filter Particulate Matter Fumes Humiture
  CL-201-E   CL-201-WF - - CO Temp RH
  CL-202-E CL-202-WF CO2
  CL-203-E  CL-203-WF CO + CO2
  CL-204-E  CL-204-WF HCHO + TVOC
  CL-205-E  CL-205-WF NH3
  CL-206-E   CL-206-WF H2S
  CL-207-E CL-207-WF HCHO
  CL-208-E  CL-208-WF TVOC
  CL-210-E   CL-210-WF Replaceable
Filter
PM2.5 - Temp RH
CL-211 CL-211-E   CL-211-WF CO
CL-212 CL-212-E  CL-212-WF CO2
CL-213 CL-213-E CL-213-WF CO + CO2
  CL-220-E  CL-220-WF Replaceable
Filter
PM1
PM2.5
PM10
Particle
(PM Sizes: 0.3μm, 0.5μm,
1μm, 2.5μm, 5μm, 10μm)
- Temp RH
  CL-221-E    CL-221-WF CO
  CL-222-E  CL-222-WF CO2
  CL-223-E   CL-223-WF CO + CO2
  CL-224-E    CL-224-WF HCHO + TVOC
  CL-225-E CL-225-WF NH3
  CL-226-E  CL-226-WF H2S
  CL-227-E  CL-227-WF HCHO
  CL-228-E CL-228-WF TVOC
  CL-229-E CL-229-WF CO + CO2 + HCHO + TVOC

Application

Specification

System
Alarm PM1/PM2.5/PM10/CO/CO2/RH/Temperature
Real Time Clock Yes
Data Logger Yes, up to 450,000 records
Temperature Measurement
Range -10 ~ +50°C
Resolution 0.1°C
Accuracy ±0.6°C
Life Time 10 years
Humidity Measurement
Range 0 ~ 100% RH, Non-condensing
Resolution 0.1% RH, Non-condensing
Accuracy ±5% RH, Non-condensing
Life Time 10 years
Dew Point
Range Calculated using temperature and relative humidity
Resolution 0.1°C
CO Measurement
Range 0 to 1000 ppm (Electrochemical)
Resolution 1 ppm
Accuracy ±5% of measured value
Response Time 30 seconds
Warm-up Time 5 minutes
Life Time 5 years
CO2 Measurement
Range 0 to 9999 ppm (NDIR)
Resolution 1 ppm
Accuracy ±40 ppm ±3% of measured value
Response Time 120 seconds
Warm-up Time 5 minutes
Life Time 15 years
PM1/PM2.5/PM10 Measurement
Range 0 to 1,000μg/m3 ( Laser Type)
Resolution 1μg/m3
Accuracy ± 10% of FSR.
Response Time 1 seconds
Warm-up Time 20 seconds
Life Time 5 years, Customer has to replace the filter patch.
Particle
Sizes 0.3μm, 0.5μm, 1μm, 2.5μm, 5μm, 10μm
Relay Output
Channels 1 x Form A, SPST
30 VDC @ 16 A or 250 VAC @ 16 A
Ethernet
Ports 10/100 Base-TX, 8-Pin RJ-45 x1 (Auto-negotiating, Auto-MDI/MDIX, LED indicators)
COM Ports
Ports 1 x RS-485
1 x Ethernet
Protocol DCON and Modbus/RTU (RS-485)
Modbus TCP and MQTT (Ethernet)
Power
Consumption Non-PoE: 2.8 W (Max.)
PoE: 3.0 W (Max.)
Powered from Terminal Block +12 ~ +48 VDC
Mechanical
Dimensions (mm) Ø 150 x 53 (Ø x H)
Installation Ceiling Mounting/Wall Mounting
Ingress Protection Rating IP20
Environment
Operating Temperature 0 ~ 50°C
Storage Temperature -30 ~ +75°C
Humidity 10 ~ 90% RH, Non-condensing

Download